Programming
The QuickStat-TC comes with a pre-programmed default schedule. The
schedule consists of 4 periods per day which represents a typical week
day.
Period Description Associated temperature setting
Wake-up
Awayfromhome
Return home
Sleep
Default Programming
The following shows the pre-programmed default schedule in the
QuickStat-TC.
Period Setting MO TU WE TH FR SA SU
6:00A 6:00A 6:00A 6:00A 6:00A 6:00A 6:00A
8:30A 8:30A 8:30A 8:30A 8:30A --:-- --:--
5:00P 5:00P 5:00P 5:00P 5:00P --:-- --:--
11:00P 11:00P 11:00P 11:00P 11:00P 11:00P 11:00P
The Comfort (
)temperatureisusedinperiods1and3andthe
Economy (
)temperatureisusedinperiods2and4.Forexample,
whentheperiodchangesfrom1to2,thesetpointautomaticallychanges
from Comfort (
) temperature to Economy ( ) temperature.
Preset Temperatures
TheQuickStat-TCcomeswith3presettemperaturesshownasComfort
(
) temperature, Economy ( )temperatureandVacation( )
temperature. The following table shows the intended use and the default
setting of each preset temperature.
Icon Intended use A/AF modes F mode
Comfort
(when at home)
70°F(21°C) 82°F(28°C)
Economy
(when asleep or away from home)
63°F(17°C) 68°F(20°C)
Vacation
(during prolonged absence)
50°F(10°C) 50°F(10°C)
Users can also change a preset temperature by:
1. Set the desired temperature using the
buttons.
2. Press and hold the corresponding preset button (
, , or )
until the corresponding icon is displayed.
Floor Temperature Limit (AF Mode Only)
Thedefaulttemperaturelimitsare41°Fto82°F(5°Cto28°C).
Important: If your system is installed underneath laminate or
engineered wood flooring, you MUST use AF mode with the default
settings. Note the factory default is AF mode.
Modifying the Schedule Programming
The user can change the programming to better meet their lifestyle. To
do so:
1. Press Pgmtoaccesstheprogrammingmode.Period1willbe
displayed.
2. Press Day to select the day to program for the selected period. To
select the entire week, press and hold the Daybuttonfor3seconds
until all days are selected.
3. Press Hour and Min to set the start time of the selected period, or
press Clear if you want to skip the period (--:-- is displayed).
Note: If you wish to use only 2 periods, set periods “1 and 4”
or periods “2 and 3”. Early Start will not work if you set periods
“1 and 2” or periods “3 and 4”.
4. Press Pgm to select another period, or press Day to select another
day.Theyrepeatstep3.Repeatsteps3&4untilprogrammingis
complete.
5. Press Mode/Ret toexittheprogrammingmode.
Operating Modes
The QuickStat-TC has three operating modes:
Automatic Mode
Inthismode,theQuickStat-TCfollowstheprogrammedschedule.To
place the QuickStat-TC in this mode:
1. Press the Mode/Ret button until the
icon appears on the dis-
play.
2. TodisableAutomaticmode,presstheMode/Ret button to change
themodetoManualmode
.
Temporary Manual Override (in Automatic Mode )
Users can temporarily override the scheduled programming of the
QuickStat-TC. The new temperature setpoint will be used until the
beginningofthenextperiod.TotemporarilyoverridetheQuickStat-TC:
1. Press the
, or button, while the thermostat is in the
Automaticmode,tothenewdesiredsetpoint.Oncethenewsetpoint
is accepted, the icon will begin to flash.
2. To cancel the temporary override, press the Mode/Ret button.
Manual Mode
Inthismode,theprogrammedscheduleisnotusedandthesetpoint
temperature must be set manually. To place the QuickStat-TC in this
mode:
1. Press the Mode/Ret button until the
icon appears on the
display.
2. Set the temperature using the
, or button.
3. TodisableManualmode,presstheMode/Ret button to change the
modetoAutomaticmode
.
QuickStat-TC Installation & Operation Manual