The QuickNet-RK repair kit is for repairing heating cable that is damaged
during installation of the QuickNet mat. The kit includes jumper wires to
bridge the heating element after the damaged section is removed. The kit
contents are sufficient to repair one damaged section up to 5 inches long. If
more than 5 inches of cable has been damaged, the mat must be replaced.
Tools Required
Wire Strippers 16-26 AWG Heat gun (1000˚F air temp
Gloves with heat deflector required)
• Scissors Multimeter (capable of 200K ohms)
Other Required Materials
QuickNet System Installation Manual (H57704)
QuickStat Thermostat Installation and Operation Manual (H57725)
Optional Tile Removal Tools
• Grout removal tool Hammer
Approvals
Radiant Floor HeatingRadiant Floor Heating
WARNING: Shock and Fire Hazard.
If the QuickNet mat is damaged or not installed
properly, fire or shock could occur resulting in
serious personal injuries or damage to property. You
must carefully follow the warnings and instructions
contained in these instructions and the QuickNet
Installation Manual (H57704). Contact Tyco Thermal
Controls for assistance.
The QuickStat thermostat must be used. It has a
ground-fault circuit interrupter (GFCI) to prevent
electric shock.
The QuickNet-RK repair kit must be installed
by qualified personnel familiar with generally
accepted construction techniques and safe electrical
practices. The installation must comply with all
national and local electrical codes. If you are
unfamiliar with these requirements, contact a
licensed electrician.
Electric wiring and the heating mat are installed
in the floor. Be sure that the floor is not penetrated
by nails, screws, or similar devices that can cause
damage on first installation or during subsequent
floor repairs in the future.
Do not use this Repair Kit to splice different QuickNet
mats together. It is designed only to repair a damaged
section of heating cable in a single mat.
The QuickNet heating cable cannot be cut to length,
crossed over itself, or installed closer than the
spacing in the mat.
QuickNet mats can only be installed beneath ceramic
tile or natural stone surfaces. Do not install beneath
wooden, carpeted, linoleum, or other type floors.
Do not step directly on or damage the heating cable
during installation.
Do not install the QuickNet mat across expansion
joints.
Follow the manufacturer’s instructions for installing
tiles, scratch coat, thin-set mortar, or quick drying
mortar beds.
Do not allow heating cable, cold lead, or floor
temperature sensor to cross over themselves or
each other.
Installation Instructions
QuickNet-RK
QuickNet
Heating Cable Repair Kit
Kit Contents:
Item Qty Description
A 2 Jumper wires (blue)
B 6 SolderSleeve
®
connectors
C 4 Heat-shrinkable tubing
D 1 Ground wire (non-insulated)
A
B
C
D
The QuickNet-RK Repair Kit is for making minor repairs
to the QuickNet heating cable if it is damaged during or
after installation. Because the condition of the damaged
mat, site conditions and installer capability can vary,
Tyco Thermal Controls does not warrant the repair or
warrant that the repaired floor warming system will
function properly. Use of this kit voids the warranty
of the repaired portion of the heating cable. Repairs
should only be attempted by a qualified electrician or
experienced craftsmen familiar with good electrical
practice and techniques for tile installation and removal.
Contact Tyco Thermal Controls for assistance.
WARRANTY & APPROVALS DISCLAIMER
WARNING:
INSTALLATION GUIDELINES:
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - QuickNet-RK

DescriptionThe QuickNet-RK repair kit is for repairing heating cable that is damaged during installation of the QuickNet mat. The kit includes jumper

Seite 2 - 240/(120)VAC

QuickNet-RK Installation Instructions213 45• Turn off the power to the QuickNet floor warming system at the circuit breaker before starting any repa

Seite 3

QuickNet-RK Installation Instructions37• Remove sufficient mortar to expose 4-5 inches of heating cable on either side of the damage. Using scissors

Seite 4

QuickNet-RK Installation Instructions4• Twist two ground wires together.• Heat only 1/2" of the insulated ends of the heating elements to soft

Seite 5

QuickNet-RK Installation Instructions5• Strip 1/2" of insulation off both ends of each jumper wire.• Slide SolderSleeve connector onto one hea

Seite 6 - 1/2"

QuickNet-RK Installation Instructions6• Cut ground jumper to length, allowing 1/2" overlap on each end of twisted grounding wire.• Slide Solde

Seite 7 - Testing Procedure

QuickNet-RK Installation Instructions7 This test ensures that the insulating jackets of the mat are not damaged. A low value indicates the mat has be

Seite 8 - Project data

QuickNet-RK Installation Instructions8© 2006 Tyco Thermal Controls LLC Printed in USA P000000662 H57959 07/06Worldwide HeadquartersTy